Spindle Start Time
- From Power-on to Drive Ready 2
- From Power-on to Rotational Speed 3
4.5s average
4.5s average
Spindle Stop Time
5.1s average
Load/Unload Cycles at Ambient Condition
600,000
1 When measuring seek times, the average latency must be subtracted from read, write, or explicit seek commands. 2 Defined as the time from power-on to the setting of Drive Ready and Seek Complete including calibration. 3 Defined as the time from power-on to when the full spindle rotational speed is reached.
5-500 Hz, 2.0g (0 to peak), 0.5 octaves/min. 5-500 Hz, 0.05 g2/Hz (0 to peak)
Sweep Rate
0.5 octave/minute minimum
Drive Generated Vibration
Operating
0.2 gm-mm average with the drive in an unconstrained condition
Rotational Shock Non-Operating
Amplitude
30K rad/sec2
Duration
2 ms
Operating Temperature and Humidity
Temperature 1
5°C to 60°C (41°F to 140°F) on base
Humidity
8-90% RH non-condensing 29.4°C (maximum wet bulb)
Thermal Gradient
20°C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
Non-Operating Temperature and Humidity
Temperature
-40°C to 65°C (-40°F to 149°F)
Humidity
5-95% RH non-condensing 40°C (maximum wet bulb)
Thermal Gradient
30°C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
Altitude
Operating
-1000 feet to 10,000 feet (-305M to 3,050M)
Non-Operating
-1000 feet to 40,000 feet (-305M to 12,200M)
Acoustics
Typical Sound Power Level 2
Idle Mode 3
20 (average dBA)
Seek Mode 4, 5
21 (average dBA)
Reliability Specifications
AFR
<0.5%
Component Design Life
5 years
1 The system environment must allow sufficient air flow to limit surface temperatures as defined. 2 Measured per ECMA-74/ISO 7779. 3 No audible pure tones. 4 Random seek at a rate of 26 seeks per second. 5 Seek mode selectable with the Automatic Acoustic Management feature.